Propaq CS

Baxter · Patient Monitors

Open your document

Propaq CS Monitor, Service Manual

Service ManualOEM officialEN
Open ↗

Welch Allyn Propaq CS Service Manual

Service ManualArchive copyEN
Open ↗

GCX M-Series Wall Mount Kit for Welch Allyn Propaq CS Monitor, Installation Guide

Other DocumentOEM officialEN
Open ↗

Net Off Card for Propaq CS, Reference

Other DocumentOEM officialEN
Open ↗

Propaq CS Vital Signs Monitor, Models 242, 244, 246 Software version 3.7X, User Manual

Operator's ManualOEM officialEN
Open ↗

Welch Allyn Patient Monitor Propaq CS Vital Signs Monitor Service Manual

Operator's ManualArchive copyEN
Open ↗

Wlech Allyn Patient Monitor Propaq CS Vital Signs Monitor Service Manual

Operator's ManualArchive copyEN
Open ↗

Stuck? Start here

✅ Check the simple stuff first
  1. Make sure the patient is safe — swap in a backup unit if you need to.
  2. Reproduce the complaint yourself and write down exactly what you see (screen, alarm, code).
  3. Check power, battery, cables, accessories, and settings before ordering parts.
  4. Then open the service manual above and follow its troubleshooting section.
🛠️ Common faults for Propaq CS (5)

'PROGRAM FAULT: SETTINGS LOST, TIME/DAY RESET' source ↗

  • Usually a drained internal battery: replace and reprogram time/settings

'CUFF FAULT: NIBP DISABLED' source ↗

  • Functional check and calibrate NIBP; repair as needed

'CALIBRATION ERROR, TEMP DISABLED' source ↗

  • Check power supply values; analog board may need replacement

Mainstream CO2 sensor / adapter messages source ↗

  • Clean or replace airway adapter (cuvette)
  • Replace sensor for EEPROM/heater/motor/calibration failures

Sidestream CO2 pump/occlusion messages source ↗

  • Fix kinked tubing / exhaust occlusion
  • Persisting: replace SSP or Stick board
🔢 Propaq CS error codes (1)
CodeMeaningNext step
x-yyy-zzzzNon-recoverable error (x: 0 DCP, 1 DAP, 2 printer, 3 SpO2, 5 MSP CO2, 7 sidestream)Monitor locked out; return to Welch Allyn service source ↗
🧰 Common checks for Patient Monitors (1)

Leads off / no signal (telemetry) source ↗

  • Re-attach ECG leads
  • Confirm transmitter is in coverage and batteries are good
📞 Still stuck? Call Baxter

Contact Baxter US

📞 Tech support
1-800-535-6663, option 2
🛠️ Service
1-800-445-3720 (Hillrom beds/stretchers/lifts parts, service, tech support)
✉️ Email
[email protected]
🌐 Portal
Support portal ↗
🔩 Parts
Order parts ↗

Welch Allyn monitoring/cardiology: 800-535-6663 opt 2. Hillrom beds service email [email protected], parts [email protected]. Sigma Spectrum pumps: 1-800-843-7867 (catalog.baxter.com/baxterUS/en/contactus). Fee-based tech support for beds/stretchers without contract since 2025-03-31.

Source ↗

Missing a manual, code, or fix for this model? Tell us.