Progressa

Baxter · Hospital Beds

Open your document

Progressa Bed Service Manual

Service ManualOEM officialEN
Open ↗

Hillrom Progressa ICU Hospital Bed - Instructions for Use Rev 20

Operator's ManualOEM officialEN
Open ↗

Progressa Bed System with the Accella Therapy Mattress Upgrade Instructions and Instructions for Use

Operator's ManualOEM officialEN
Open ↗

Progressa P7501A Bed - Instructions for Use Rev 5

Operator's ManualOEM officialEN
Open ↗

Progressa P7501A Bed - Instructions for Use Rev 6

Operator's ManualOEM officialEN
Open ↗

Progressa P7501A Bed - Instructions for Use Rev 8

Operator's ManualOEM officialEN
Open ↗

Progressa® Bed Instructions for Use

Operator's ManualOEM officialEN
Open ↗

Progressa® Bed Instructions for Use Rev 15

Operator's ManualOEM officialEN
Open ↗

Progressa® Bed Instructions for Use Rev 16

Operator's ManualOEM officialEN
Open ↗

Progressa® Bed Instructions for Use Rev 17

Operator's ManualOEM officialEN
Open ↗

Stuck? Start here

✅ Check the simple stuff first
  1. Make sure the patient is safe — swap in a backup unit if you need to.
  2. Reproduce the complaint yourself and write down exactly what you see (screen, alarm, code).
  3. Check power, battery, cables, accessories, and settings before ordering parts.
  4. Then open the service manual above and follow its troubleshooting section.
🛠️ Common faults for Progressa (7)

Service indicator on the caregiver panel source ↗

  • Diagnostics: view and clear the code
  • Unplug the bed and aux outlet until the GCI is off, then replug
  • If it returns, follow the table solutions in order; check the cables and binding parts first

Code series → board source ↗

  • 1000 UCB (16830201), 2000 SideCom (16010201), 3000 Air Control (17172001), 4000 GCI (16678801), 9000 OIML scale (16795301), A000 Pneumatic (16805401/17209301), B000 Wireless module

Battery / charging (1040–1049) source ↗

  • Charge overnight; check the cables; replace batteries or LCB
  • Transport mode (1049): AC for 30 min

Articulation fails / over-current or position errors source ↗

  • Replace the named drive; recalibrate the bed position (1157)

Scale errors source ↗

  • Recalibrate (1180); replace the red load beam (1182); UCB for 1181/1183
  • Run the accuracy check in Specified Checks

Therapy surface faults (Max-Inflate, AMT, Turn Assist) source ↗

  • Use the mattress fault procedures: Leak, Air Distribution, Sensor, Fan, Blower, Inflation

After repair source ↗

  • Update software after a UCB/ACB/DCB/SCB swap; run the Function Checks on both sides
🔢 Progressa error codes (24)
CodeMeaningNext step
1040/1041Battery voltage lowCharge overnight; replace batteries source ↗
1042Battery voltage too highCheck battery cables source ↗
1043/1044Battery charging current faultReplace Lower Control Board source ↗
1045LCB SPI commCheck the UCB–LCB cable source ↗
1046/1047Charge time exceeded / voltage can't riseReplace batteries source ↗
1048Battery temp out of rangeWon't clear until the bed is in its operating temperature range source ↗
1049Bed in transport modePlug into AC for 30 min source ↗
1080–1083EEPROM write/read/critical errorReplace Upper Control Board source ↗
10C0CPR switch failedReplace the head drive (contains the CPR switch) source ↗
10C1Pendant failedReplace pendant source ↗
1100Lost CAN (UCB)Replace UCB source ↗
1141Motor over voltageReplace UCB source ↗
1142–1151Motor or hardware over-current (HiLo head/foot, head, knee, foot/FlexAfoot, leg)Replace the named drive; then UCB source ↗
1148/1149/114A/1153–1156Position errors (HiLo, head, knee, foot, FlexAfoot, head angle)Replace the named drive (position sensor) source ↗
1157Bed frame positionRe-calibrate bed position source ↗
1158Chair exit positionRe-calibrate scale source ↗
1180Scale calibrationRe-calibrate scale source ↗
1181/1183Scale heartbeat missing / ADC errorReplace UCB source ↗
1182Load beam dataReplace the load beam showing red source ↗
Mattress 1001/1002Low / high pressureMattress Leak / Air Distribution fault procedures source ↗
Mattress 1004Pressure sensor errorReplace MCB (212418) source ↗
Mattress 1009Mattress battery very lowReplace battery (A39005) source ↗
Mattress 1011/1012/1014Fan low, blower disconnected, P-Max not reachedFan, Blower, or Inflation fault procedures source ↗
Mattress 1215/1225Mattress connection lostCheck the cable connections source ↗
🧰 Common checks for Hospital Beds (1)

Function doesn't move source ↗

  • Check lockout controls
  • Head stuck after manual CPR lowering: reset CPR per IFU
📞 Still stuck? Call Baxter

Contact Baxter US

📞 Tech support
1-800-535-6663, option 2
🛠️ Service
1-800-445-3720 (Hillrom beds/stretchers/lifts parts, service, tech support)
✉️ Email
[email protected]
🌐 Portal
Support portal ↗
🔩 Parts
Order parts ↗

Welch Allyn monitoring/cardiology: 800-535-6663 opt 2. Hillrom beds service email [email protected], parts [email protected]. Sigma Spectrum pumps: 1-800-843-7867 (catalog.baxter.com/baxterUS/en/contactus). Fee-based tech support for beds/stretchers without contract since 2025-03-31.

Source ↗

Missing a manual, code, or fix for this model? Tell us.